1,322 research outputs found

    The non-linear evolution of bispectrum from the scale-free N-body simulation

    Full text link
    We have accurately measured the bispectrum for four scale-free models of structure formation with the spectral index n=1n=1, 0, -1, and -2. The measurement is based on a new method that can effectively eliminate the alias and numerical artifacts, and reliably extend the analysis into the strongly non-linear regime. The work makes use of a set of state-of-the art N-body simulations that have significantly increased the resolution range compared with the previous studies on the subject. With these measured results, we demonstrated that the measured bispectrum depends on the shape and size of kk-triangle even in the strongly nonlinear regime. It increases with wavenumber and decreases with the spectral index. These results are in contrast with the hypothesis that the reduced bispectrum is a constant in the strongly non-linear regime. We also show that the fitting formula of Scoccimarro & Frieman (1999) does not describe our simulation results well (with a typical error about 40 percent). In the end, we present a new fitting formula for the reduced bispectrum that is valid for −2≀n≀0-2 \leq n \leq 0 with a typical error of 10 percent only.Comment: 33 pages, including 1 table, 14 figures, accepted by Ap

    Carbonyl{3,3â€Č-di-tert-butyl-5,5â€Č-dimethoxy-2,2â€Č-bis[(4,4, 5,5-tetramethyl-1,3,2-dioxaphospholan-2-yl)oxy]biphenyl-Îș2 P,Pâ€Č}hydrido(triphenylphosphane-ÎșP)rhodium(I) diethyl ether trisolvate

    Get PDF
    In the title compound, [RhH(C74H68O8P2)(C18H15P)(CO)]·3C4H10O, the CHP3 coordination set at the RhI ion is arranged in a distorted trigonal-bipyramidal geometry with the P atoms adopting equatorial coordination sites and the C atom of the carbonyl ligand as well as the H atom adopting the axial sites. The asymmetric unit contains two very similar molecules of the rhodium complex, two half-occupied diethyl ether molecules and further diethyl ether solvent molecules which could not be modelled successfully. Therefore contributions of the latter were removed from the diffraction data using the SQUEEZE procedure in PLATON [Spek (2009). Acta Cryst. D65, 148-155]

    A cosmological model in Weyl-Cartan spacetime

    Get PDF
    We present a cosmological model for early stages of the universe on the basis of a Weyl-Cartan spacetime. In this model, torsion TαT^{\alpha} and nonmetricity QαÎČQ_{\alpha \beta} are proportional to the vacuum polarization. Extending earlier work of one of us (RT), we discuss the behavior of the cosmic scale factor and the Weyl 1-form in detail. We show how our model fits into the more general framework of metric-affine gravity (MAG).Comment: 19 pages, 5 figures, typos corrected, uses IOP style fil

    Crystal structure of (2,3-bis((2R,5R)-2,5-dimethylphosphonalyl)maleic anhydride)-(η4-norbornadiene)-rhodium(I) tetrafluoroborate, [Rh(C7H8)(C16H24O3P 2)] [BF4]

    Get PDF
    C23H32BF4O3P2Rh, orthorhombic, P212121 (no. 19), a = 10.147(2) Å, b = 13.246(3) Å, c = 18.827(4) Å, V = 2530.5 Å3, Z = 4, Rgt(F) = 0.025, wRref(F 2) = 0.067, T = 200 K. © by Oldenbourg Wissenschaftsverlag,

    Stick, Flick, Click: DNA-guided Fluorescent Labeling of Long RNA for Single-molecule FRET

    Full text link
    Exploring the spatiotemporal dynamics of biomolecules on a single-molecule level requires innovative ways to make them spectroscopically visible. Fluorescence resonance energy transfer (FRET) uses a pair of organic dyes as reporters to measure distances along a predefined biomolecular reaction coordinate. For this nanoscopic ruler to work, the fluorescent labels need to be coupled onto the molecule of interest in a bioorthogonal and site-selective manner. Tagging large non-coding RNAs with single-nucleotide precision is an open challenge. Here we summarize current strategies in labeling riboswitches and ribozymes for fluorescence spectroscopy and FRET in particular. A special focus lies on our recently developed, DNA-guided approach that inserts two fluorophores through a stepwise process of templated functionality transfer and click chemistry

    Precision Measurement of the 29Si, 33S, and 36Cl Binding Energies

    Full text link
    The binding energies of 29Si, 33S, and 36Cl have been measured with a relative uncertainty <0.59×10−6< 0.59 \times 10^{-6} using a flat-crystal spectrometer. The unique features of these measurements are 1) nearly perfect crystals whose lattice spacing is known in meters, 2) a highly precise angle scale that is derived from first principles, and 3) a gamma-ray measurement facility that is coupled to a high flux reactor with near-core source capability. The binding energy is obtained by measuring all gamma-rays in a cascade scheme connecting the capture and ground states. The measurements require the extension of precision flat-crystal diffraction techniques to the 5 to 6 MeV energy region, a significant precision measurement challenge. The binding energies determined from these gamma-ray measurements are consistent with recent highly accurate atomic mass measurements within a relative uncertainty of 4.3×10−74.3 \times 10^{-7}. The gamma-ray measurement uncertainties are the dominant contributors to the uncertainty of this consistency test. The measured gamma-ray energies are in agreement with earlier precision gamma-ray measurements.Comment: 13 pages, 4 figure

    Crystal structure of (η4-norborna-2,5-dien)-(1,2-bis((R,R)-2,5-bis-(methoxymethyl)phospholanyl)benzene)rhodium(I) tetrafluoroborate, [Rh(C22H36O4P2)(C7H8)](BF4)

    Get PDF
    C29H44BF4O4P2Rh, monoclinic, P21 (no. 4), a= 10.119(2) Å, 6= 14.125(3) Å, c = 11.542(2) Å, ÎČ = 106.87(3)°, V = 1578.7 Å3, Z= 2, Rgt(F) = 0.034, wRref(F2) = 0.090, T = 200 K

    Lippen-Kiefer-Gaumen-Spalten: Individuelle Analyse der Lippenspalte durch 3-D-Lasertopometrie

    Get PDF
    Zusammenfassung: Hintergrund: Mit Gipsmodellen und Fotografien ist die dreidimensionale Analyse einer Lippen-Kiefer-Gaumen-Spalte meist nur unzureichend möglich. Ziel der vorliegenden Studie war es daher, die 3-D-Lasertopometrie auf ihre Anwendbarkeit zur dreidimensionalen Weichgewebserfassung bei Patienten mit Lippen-Kiefer-Gaumen-Spalten zu testen. Patienten und Methode: Bei 20 Patienten (3-35 Jahre), die eine einseitige, nicht operierte Lippen-, Lippen-Kiefer- oder Lippen-Kiefer-Gaumen-Spalte aufwiesen, wurde mit einem 3-D-Laserscanner die GesichtsoberflĂ€che prĂ€- und postoperativ dreidimensional erfasst. Die dabei erzeugten digitalen DatensĂ€tze wurden in einer virtuellen Umgebung metrisch analysiert und anhand von Quotienten grĂ¶ĂŸenunabhĂ€ngig wiedergegeben. Sie dienten der Auswahl der Operationstechnik und der Beurteilung des Operationsergebnisses. Ergebnisse: Mit dem 3-D-Laserscanner wurden 3-D-OberflĂ€chen guter QualitĂ€t erstellt, die sich im Millimeterbereich ausmessen ließen. Die dreidimensionale Spaltmorphologie konnte in den DatensĂ€tzen reproduzierbar mit Landmarks versehen und vermessen werden. Auch die postoperative Symmetrie ließ sich so kontrollieren und objektivieren. Als nachteilig erwiesen sich die relativ lange Messzeit und die Notwendigkeit zur Kombination mehrerer Ansichten. Schlussfolgerung: Das vorgestellte 3-D-Laserverfahren ermöglicht eine prĂ€zise dreidimensionale Weichteilanalyse der Lippen- und Nasenregion bei Spaltpatienten. Es eignet sich jedoch nur bedingt fĂŒr lebhafte SĂ€uglinge und unkooperative Patiente

    User-modelled ambient feedback for self-regulated learning

    Get PDF
    A fundamental objective of human-computer interaction research is to make systems that are seamlessly integrated into daily life activities. Hence, the challenge is not only to make information available to people at any time, at any place, and in any form, but specifically to say the right thing at the right time in the right way. On the other hand, the proliferation of sensor technology is facilitating the scaffolding and customization of smart learning environments. This manuscript presents an ecology of resources comprising NFC, BLE and Arduino technology, orchestrated in the context of a learning environment to provide smoothly integrated feedback via ambient displays. This ecology is proposed as a suitable solution for self-regulated learning, providing support for setting goals, setting aside time to learn, tracking study time and monitoring the progress. Hereby, the ecology is described and intriguing research questions are introduced
    • 

    corecore